CCD外观检查机

The medical equipment is close to the verification period, the supervision organization provides "one-stop" service

2020-02-19 14:35:59
Times

Doctors can't make accurate diagnosis without the inspection data of medical equipment such as B-ultrasonic machine electrocardiograph, which requires that the medical equipment used must be intact reliable, the data obtained must be accurate. During the epidemic, Tongzhou District Market Supervision Bureau went deep into the medical institutions under its jurisdiction to "check up" "pulse" the medical equipment currently in use. For the medical measuring equipment in use that is about to reach the verification period, one-stop full service will be provided, including on-site verification, free detection rapid approval.

On February 27, three "fully armed" Tongzhou District Market Supervision Bureau staff came to the Langfu health hospital in Xiji Town, wearing white coats, protective caps white masks, pulling the black trolley box, carried out on-site inspection on 23 medical measuring instruments of the hospital.

The staff first came to the B-ultrasound room, took out a black instrument the size of a computer mainframe the black pull rod box, connected with the cable of the B-ultrasound machine, injected media into the top of the instrument. "This instrument is a biomimetic tissue ultrasonic body film, which can simulate human organs, is specially used to check whether the data of B-ultrasonic machine is accurate." The staff moved the probe of B-ultrasonic back forth in the medium, the display screen of B-ultrasonic immediately showed clear data image. After comparing the simulated situation of the inspection instrument with the data conclusion drawn by the B-ultrasonic machine, it shows that the equipment meets the requirements of the national standard. After the staff record the inspection data in detail, the equipment is labeled with the inspection qualification mark on the spot.

When checking the electrocardiograph, the staff took out the special white instrument with the words of "intelligent cardio EEG machine, electrocardiograph monitor calibrator" the pull rod box, connected the lead of the electrocardiograph with the interface of the calibrator. As the screen data of the calibrator continuously beat, the electrocardiograph printed out different waveforms. "This calibrator can simulate the ECG signal of human body get the error value of the tested equipment in real time." The staff took the printed ECG in their hands circled the key peaks one by one. It took more than 10 minutes to complete the comparison record between the data of the calibrator the printed ECG.

Subsequently, the hospital's medical staff handed over nearly 11 mercury sphygmomanometers 8 electronic sphygmomanometers to the staff. The staff of the market supervision bureau verified them through the "sphygmomanometer intelligent standard device". All sphygmomanometers met the requirements of national standards.

Li zongkui, director of the medical inspection office of the measurement Testing Institute of Tongzhou District Market Supervision Bureau, said that in order to ensure the accuracy safety of the medical measurement equipment in use during the epidemic period, Tongzhou District Market Supervision Bureau has combed all the medical measurement equipment in use in the whole region that are about to arrive at the verification period, contacted the affiliated medical institutions, provided you with a one-stop full-time service of on-site verification, free detection rapid approval Business. During the outbreak, the verification of medical measuring instruments in two key medical institutions has been completed.


label